View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0003372 | MMW v4 | Other | public | 2007-08-09 14:25 | 2009-02-20 00:33 |
Reporter | rusty | Assigned To | |||
Priority | urgent | Severity | minor | Reproducibility | always |
Status | closed | Resolution | fixed | ||
Product Version | 3.0 | ||||
Fixed in Version | 3.1 | ||||
Summary | 0003372: Skins: Micromonkey displays incorrectly in some cases | ||||
Description | The new MM3 micromonkey skins behave incorrectly in a couple of cases (originally this was reported as skin problems, but the fact that it's common to all both Glass and Casino skins seems to indicate a code problem). 1) What happens is that when the space available next to the tray isn't wide enough to accomodate the MicroMonkey skin, the portion of the skin containing the Seekbar is made narrower. This isn't a problem on its own except that when this occurs: -The right side of the seek bar is cut off -The volume slider is cut off, but the volume knob appears in the middle of the seek bar -On the casino skins, the Close/Restore buttons appear in the wrong location -If the user makes more space for the MicroPlayer, the seekbar doesn't resize I would suggest that the best solution is that the MicroPlayer's seekbar should never dynamically adjust. i.e. it should always appear as specified by the skin designer. Note: because of this issue, it's impossible to evaluate whether the width of the seekbar is set correctly for the Casino/Glass skins, so we should examine that after fixing this. 2) If you switch to the Micro Player and then move the windows start bar from it's horizontal position into a vertical position (to activate the vertical player) the play button disappears and is replaced with the default skins button overlay, then when you move the start bar back to it's horizontal position the play button is still broken. This same bug happens with all 3 skins. | ||||
Tags | No tags attached. | ||||
Fixed in build | 1191 | ||||