View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0010484 | MMW v4 | Synchronization | public | 2013-02-05 17:56 | 2013-02-14 04:32 |
Reporter | Ludek | Assigned To | |||
Priority | urgent | Severity | minor | Reproducibility | random |
Status | closed | Resolution | fixed | ||
Product Version | 4.1 | ||||
Target Version | 4.1 | Fixed in Version | 4.1 | ||
Summary | 0010484: MM can freeze on startup when an inaccessible MTP device is plugged over USB | ||||
Description | While testing I found that MM frozen on startup. It was caused by my Galaxy Nexus connected via USB in MTP mode. The device was in a strange state, because it couldn't be accessed by Windows Explorer too. The result was that MM doesn't start at all until I unplugged the device. | ||||
Tags | No tags attached. | ||||
Fixed in build | 1624 | ||||