View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0012054 | MMW v4 | Install/Config | public | 2014-05-20 02:40 | 2014-05-22 21:04 |
Reporter | peke | Assigned To | |||
Priority | immediate | Severity | major | Reproducibility | always |
Status | closed | Resolution | fixed | ||
Product Version | 4.1.2 | ||||
Target Version | 4.1.2 | Fixed in Version | 4.1.2 | ||
Summary | 0012054: Inaccessible folders: Settings should be reverted to defaults | ||||
Description | When user backup INI paths to Virtual CD and previews are pointing to inaccessible path and can lead to MMW crash on startup. In case they are not accessible values for them should be Reset to defaults. | ||||
Additional Information | Ticket: HKD-605-37447 | ||||
Tags | No tags attached. | ||||
Fixed in build | 1705 | ||||
|
We should keep in mind that the locations could be inaccessible only temporarily. Therefore the solutions could be: 1) Change it to default, but doesn't save the settings (save it only once the paths are not defaults) 2) Change them to default only once they are really needed with write access (not during settings reading as currently) |
|
Fixed using solution 1) in build 1705. |
|
Verified 1705 |