View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0013238 | MMW v4 | Synchronization | public | 2016-04-20 23:53 | 2016-05-24 00:36 |
Reporter | peke | Assigned To | |||
Priority | urgent | Severity | crash | Reproducibility | sometimes |
Status | closed | Resolution | fixed | ||
Target Version | 4.1.12 | Fixed in Version | 4.1.12 | ||
Summary | 0013238: Device removal: MMW can crash on USB cable disconnect | ||||
Description | Sometimes if usb is removed when MMW tree is focused on Device profile can result in crash. | ||||
Tags | No tags attached. | ||||
Attached Files | |||||
Fixed in build | 1796 | ||||
|
Fixed in 1788 |
|
Verified 1789 |
|
Re-opened, Rusty still observes crash on disconnect with "Amazon Fire HD" device. ELF submitted. |
|
Fixed in 1792. |
|
Verified 1793 Moto G |
|
Re-opened: As found by Marek (and also reproducible by me now) there is a regression, USB sync now freezes when USB cable is disconnected during file copying. Not sure why I didn't observe this while fixing and why Peke haven't found this while veryfing, but seems to be consistently reproducible for me now. Fixed in 1796. |
|
You were right about teh reason I was not detecting it Verified 1796 |