View Issue Details

IDProjectCategoryView StatusLast Update
0002457MMW v4Synchronizationpublic2006-04-18 03:15
Reporterrusty Assigned To 
PriorityimmediateSeveritymajorReproducibilityalways
Status closedResolutionfixed 
Summary0002457: Regression: Numerous synchronization problems when Synching to MTP devices
DescriptionNumerous problems with MTP synchronization:

1) When 'Delete tracks that aren't on the synch list' is enabled, Tracks that are on the device that should be deleted aren't
2) When 'Delete tracks that aren't on the synch list' is enabled, only _one_ of the playlists that are on the device are prompted for deletion (if I synch again, then the next playlist is prompted for deletion, but each time, only 1 playlist is promtped)
3) If tracks already exist on the device, they are resynched (even though MediaMonkey should detect that they already exist)

Note: I've tested this with both the iRiver PMC-120 and the Creative Vision and the bugs occur with both devices.

I need to test with other devices...
TagsNo tags attached.
Fixed in build964

Activities

jiri

2006-04-17 19:42

administrator   ~0007146

Fixed in build 964.

rusty

2006-04-18 03:15

administrator   ~0007149

Verified on build 954 with Creative Vision, PMC 120, H10, Creative Sleek, and iFP880 devices.