View Issue Details

IDProjectCategoryView StatusLast Update
0006620MMW v4Synchronizationpublic2010-11-07 20:37
Reporterjiri Assigned To 
PriorityimmediateSeveritymajorReproducibilityalways
Status closedResolutionfixed 
PlatformWindowsOS7OS Version-
Product Version4.0 
Target Version4.0Fixed in Version4.0 
Summary0006620: Device configuration should disappear when a device is disconnected
DescriptionWhen a device is disconnected while its node is focused and thus also device configuration is shown, it should disappear. Note, that user should be asked for saving the config, if necessary.
TagsNo tags attached.
Fixed in build1321

Relationships

related to 0006653 closedLudek Disconnection of MTP Device --> AV 

Activities

jiri

2010-11-01 19:16

administrator   ~0021115

Setting as Immediate, since it seems to me that it can cause subsequent AV on closing of MM.

Ludek

2010-11-03 14:41

developer   ~0021146

Fixed in build 1321.

rusty

2010-11-07 20:37

administrator   ~0021225

This is fixed in most cases, except for the occasional problem that is described in bug 0006653.