View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0007868 | MMW v4 | Synchronization | public | 2011-05-23 11:52 | 2011-09-17 23:01 |
Reporter | jiri | Assigned To | |||
Priority | urgent | Severity | minor | Reproducibility | always |
Status | closed | Resolution | fixed | ||
Platform | Windows | OS | 7 | OS Version | - |
Product Version | 4.0 | ||||
Target Version | 4.0 | Fixed in Version | 4.0 | ||
Summary | 0007868: Whenever a device is being scanned, it can't be Ejected | ||||
Description | As probably reported in http://www.mediamonkey.com/forum/viewtopic.php?f=6&t=58108 , while a device is being scanned, it can't be Ejected. We should stop scanning first. | ||||
Tags | No tags attached. | ||||
Fixed in build | 1382 | ||||
|
Fixed in build 1379. |
|
When I click the Eject button, there is '(Scanning)' text shown at least for a while (when auto-scanning is disabled). I wonder whether this could have caused that a user still reports that his device can't be Ejected (http://www.mediamonkey.com/forum/viewtopic.php?f=6&t=58108 ) |
|
There was also occassional AV in my case. Fixed in build 1382. |
|
Too early verification with 1387 althum two devices worked and eject was possible. SD card inserted in Card reader was locked by MM. Force Disconnect in Zentimo app unlocked it and ejected it. EDIT: Tried to repro steps without success. All three devices were ejected normally and on one occasion SD card was locked due System -> Write delay $MFT which do not have any relations with MM. |
|
Verified 1433 |